Sitemap Page
About Us Technology Products Client Feedback Clinical Education Contact Us
 
 
Saline Plasma Bipolar Resection
 
  Shalya Penta
 

 

 

 

See also :

 

  • COMBO Generator Technology: High Performance ESU (Diathermy) with Vessel Sealing System & Saline Plasma  Bipolar Resection, in Single Unit.

 

  • One Touch : Touch screen 7” TFT panel operation for flexible use
  • Internet Enabled : Remote programmable / calibration
  • Data Logging : Last 50 surgical cases data stored in system memory
  • Self Demonstration Mode : System gives self demonstration and settings for users
  • User Programmable : 100 user settable programs with case names helps in setting the system
  • Recall Function : Automatic last status resume
  • Auto Mode : Auto mono & bipolar mode for without foot / hand activation
  • Dual Mono Mode : Independent power and mode setting for two Monopolar channel
  • 2SiCoag : Two Simultaneous coagulation output at a time with independent control.
  • Bipolar Cut & Coag : Bipolar Cut & Coag Mode with independent settings and activation.
  • BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
  • Dual Vessel Sealing : Two Channel Vessel Sealing up to 7mm with reusable Open & Lapro attachments.
  • Auto Stops : the energy delivery with audio indication at completion of sealing.
  • Tissue ReHold alarm is given if improper grasping of tissue.
  • Saline Resection : Bipolar Saline Plasma Cut two modes & Coag two modes.
  • Saline Safety Alarm : Electrode Disconnection / Non Saline activation Alarm.
  • Cost Effective Saline use : Regular Working Element can be used with regular loops.
  • 2 Endo Mode : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
  • Argon Beam Coagulator up-gradable : ESU can be upgraded for Argon Beam Coagulation module.
  • 6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
  • PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
  • Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.

 

  • 7 Cut Modes:

            Low Cut : 400 W
            Pure Cut : 400 W
            Blend 1 Cut : 250 W
            Blend 2 Cut : 200 W
            Endo 1: 400 W
            Endo 2: 400 W
            Hydro : 400 W

  • 6 Coag Modes:

    Soft: 300 W
    Desiccate : 150 W
    Swift : 120 W
    Fulgurate: 120 W
    Spray Coag : 120 W
    Hydro: 120 W

  • 2 Bipolar Cut Modes:

    Macro Bip: 95 W
    Bipolar Cut : 95 W

  • 3 Bipolar Coag Modes:  

    Micro Bip: 95 W
    Standard: 95 W
    Force : 95 W

  • 2 Vessel Seal Modes: 

    Micro Seal: Level 1(80W) to Level 5(150W)
    Standard Seal: Level 1(80W) to Level 5(150W)

  • 2 Saline Plasma Bipolar Cut Modes:

    Saline Low: 300 W
    Saline Standard : 300 W

  • 2 Saline Plasma Bipolar Coag Modes:

    Saline Low: 300 W
    Saline Standard : 300 W

   

ESU Applications:
• Gynecology • Urology( TURP ) • Laproscopic Surgeries • Endoscopy ( ERCP ) • Oncosurgery • Heart & Chest surgery, CABG •Neurosurgery, Spine • Arthroscopy • All other general surgical procedures.

Vessel Sealer Applications:
• Abdominal Hysterectomy • Adrenalectomy • Appendectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy • Radical Prostatectomy • Splenectomy • Salpingo-oophorectomy • Vaginal Hysterectomy • Whipple

Saline Plasma Resection Applications:
•TURP • TCRE • Hysteroscopy • TCRE • Arthroscopic surgery

   
Live Video    Download Details Catalog 
 

 
  Shalya Vista
 

 

 

 

See also :

 

  • COMBO Generator Technology: High Performance ESU (Diathermy) with Vessel Sealing System & Saline Plasma  Bipolar Resection, in Single Unit.
  • One Touch : Touch screen 5.7” TFT panel operation for flexible use
  • Self Demonstration Mode : System gives self demonstration and settings for users
  • User Programmable : 100 user settable programs with case names helps in setting the system
  • Recall Function : Automatic last status resume
  • Dual Mono Mode (Optional) : Independent power and mode setting for two Monopolar channel
  • 2SiCoag (Optional): Two Simultaneous coagulation output at a time with independent control.
  • Bipolar Cut & Coag : Bipolar Cut & Coag Mode with independent settings and activation.
  • BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
  • Dual Vessel Sealing :  Vessel Sealing up to 7mm with reusable Open & Lapro attachments.
  • Auto Stops : the energy delivery with audio indication at completion of sealing.
  • Tissue ReHold alarm is given if improper grasping of tissue.
  • Saline Resection : Bipolar Saline Plasma Cut two modes & Coag two modes.
  • Saline Safety Alarm : Electrode Disconnection / Non Saline activation Alarm.
  • Cost Effective Saline use : Regular Working Element can be used with regular loops.
  • 2 Endo Mode : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
  • Argon Beam Coagulator up-gradable : ESU can be upgraded for Argon Beam Coagulation module.
  • 6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
  • PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
  • Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
  • 7 Cut Modes:

    Low Cut : 400 W
    Pure Cut : 400 W
    Blend 1 Cut : 250 W
    Blend 2 Cut : 200 W
    Endo 1: 400 W
    Endo 2: 400 W
    Hydro : 400 W

  • 6 Coag Modes:

    Soft: 300 W
    Desiccate : 150 W
    Swift : 120 W
    Fulgurate: 120 W
    Spray Coag : 120 W
    Hydro: 120 W

  • 2 Bipolar Cut Modes:

    Macro Bip: 95 W
    Bipolar Cut : 95 W

  • 3 Bipolar Coag Modes:  

    Micro Bip: 95 W
    Standard: 95 W
    Force : 95 W

  • 2 Vessel Seal Modes: 

    Micro Seal: Level 1(80W) to Level 5(150W)
    Standard Seal: Level 1(80W) to Level 5(150W)

  • 2 Saline Plasma Bipolar Cut Modes:

Saline Low: 300 W
Saline Standard : 300 W

  • 2 Saline Plasma Bipolar Coag Modes:

Saline Soft: 150 W
Saline Force : 150 W

   

ESU Applications:
• Gynecology • Urology( TURP ) • Laproscopic Surgeries • Endoscopy ( ERCP ) • Oncosurgery • Heart & Chest surgery, CABG •Neurosurgery, Spine • Arthroscopy • All other general surgical procedures.

Vessel Sealer Applications:
• Abdominal Hysterectomy • Adrenalectomy • Appendectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy • Radical Prostatectomy • Splenectomy • Salpingo-oophorectomy • Vaginal Hysterectomy • Whipple

Saline Plasma Resection Applications:
•TURP • TCRE • Hysteroscopy • TCRE • Arthroscopic surgery

   
Live Video    Download Details Catalog 
 

 
    Shalya TURoSeal (with ESU)
 

 

A Plasma Corona is generated in saline medium due to discharge of highly energized electric current. The mobility of ions around the loop creates a cutting effect. Sufficient amount of haemostasis enables coagulation of the capillary bleeders with resection. By applying low voltage energy, resistive heating of tissue achieves coagulation and the depth is controlled by firm application of pressure with sufficient amount of time to control the bleeders.

  • Combo Unit with ESU, Vessel Sealer & Saline Plasma Bipolar TURP( BiTUR) in one unit.
  • 6 SENSE Technology ESU

    ESU Module
  • ESU : 2 Bipolar Modes. Max Power – 70W
              4 Cut Modes with PULSE CUT Mode Max Power - 300W
              4 Coag Modes with low CF Fulgurate. Max Power – 120W
  • PREM Patient Return Electrode Monitoring.
  • Randomized SPRAY Coag
  • BiCoag Alarm
  • Remote Programmability : from sterile field.
  • Pulse Cut (Optional) for Polypectomy & Papillotomy.
  • User Programmable: THIRTY Surgical Programs
  • 2SiCoag (Optional): Two Simultaneous coagulation.
  • User Programs: THIRTY (TEN User Programmable)
  • Self Diagnosis
  • Argon Beam Coagulator up-gradable

    Vessel Seal Module
  • VesSeal : 5 Level sealing. Max Power – 150W
                      1 Bip Cut Mode. Max Power - 95W
                      1 Coag Mode. Max Power – 95W
     
  • Cool Seal: Innovative technology to seal the tissue vessel by applying calibrated pressure with RF energy. The Collagen & Elastin within the tissue in vessel walls melts & restructure to form a translucent seal.
  • Sealing Program: auto-select is available as per the selected accessory & grasped tissue.
  • Auto Stops: The energy delivery with audio indication at completion of sealing cycle.
  • Tissue ReHold: Alarm “CL rEHOLd” is given if Insert is closed &
    “OP rEHOLd” in case of open.
  • Bipolar Cut & Coag: Independent Display setting with independent foot-switches.
  • User Programs: ONE User Programmable
  • Reusable Attachments: Laproscopic 5 & 10mm with changeable blade & open Sealer with various sizes.

    Saline Resection Module
  • BiTUR: Saline Cut Mode. Max Power - 300W
                 Saline Mode. Max Power – 120W
  • User Programs: ONE User Programmable
  • Electrode Disconnection / Non Saline activation Alarm.
  • Regular loops can be used for saline work , hence reduces working cost.
  • Regular Working Element can be used for bipolar work.

Saline Plasma Resection: Applications -
TURP • TCRE • Hysteroscopy • TCRE • Arthroscopic surgery

   
Live Video    Download Technical Leaflet 

Download Details Catalog 
 

 
  Shalya Turoseal (without ESU)
 

 

A Plasma Corona is generated in saline medium due to discharge of highly energized electric current. The mobility of ions around the loop creates a cutting effect. Sufficient amount of haemostasis enables coagulation of the capillary bleeders with resection. By applying low voltage energy, resistive heating of tissue achieves coagulation and the depth is controlled by firm application of pressure with sufficient amount of time to control the bleeders.

  • 6 SENSE Technology ESU

    Saline Resection Module
  • BiTUR: Saline Cut Mode. Max Power - 300W
                 Saline Mode. Max Power – 120W
  • User Programs: ONE User Programmable
  • Electrode Disconnection / Non Saline activation Alarm.
  • Regular loops can be used for saline work , hence reduces working cost.
  • Regular Working Element can be used for bipolar work.

Saline Plasma Resection: Applications -
TURP • TCRE • Hysteroscopy • TCRE • Arthroscopic surgery

   
Live Video    Download Technical Leaflet 

Download Details Catalog 
 

 
Top
 
 
Copyright © 2010 XCELLANCE Medical Technologies      This site best viewed in 1024 x 768
Site Designed ByWEB - MANTRA
Home Page Careers Page Sitemap PAge info@xcellancetech.com